Summary for Test 2023-07-18-40-2
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 993844 DEA: 070W1004 EFIS: 0721000043 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-31.8/42.6 |
Award Date | 06/28/2022 |
Closeout Date | Not set |
Work Description | PLACE RUBBERIZED HMA (GAP GRADED) |
Location Description | LOS ANGELES COUNTY IN BURBANK AND LOS ANGELES FROM COHASSET STREET UNDERCROSSING TO ROXFORD STREET UNDERCROSSING |
QA Service Level | 1 (Verified on 09/20/2022) |
Sample Information
Sample Taken Date | 07/18/2023 | Sample Unique Key | 40 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/20/2023 |
Sample type | Department Acceptance | A brief description of the sample | 3/4" RHMA-G 226108 SVA3 LTR |
The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Victor | Last name of sampler or witnessed by | Pham |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | 23-273 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Materials Sun Valley | Transportation Laboratory (TL) Number | 0718A1 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | 226108 SVA3 LTR |
Test Details
DIME Sample ID: 2023-07-18-40
DIME Test ID: 2023-07-18-40-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-07-24
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Philip Maquiran
Date of test: 07/24/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 4027.1 g
Mass of the specimen and specimen basket assembly prior to ignition: 6079.6 g
Mass of HMA Sample prior to ignition: 2052.5 g
Mass Loss: 155.9 g
Mass of aggregate remaining after ignition: 1896.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.32 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.28 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/24/2023 ✔