Summary for Test 2023-05-23-52-2

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 993508
DEA: 070W1104
EFIS: 0721000059
DIST-CO-RTE-PM07-LA-210-R35.9/R52.2
Award Date04/04/2022
Closeout Date09/24/2024
Work DescriptionCOLD PLANE OVERLAY, INDIVIDUAL REPLACEMENT SLAB AND TRAFFIC STRIPING.
Location DescriptionLOS ANGELES COUNTY FROM HIGHLAND AVENUE UNDERCROSSING IN DUARTE TO SAN ANTONIO WASH BRIDGE IN CLAREMONT.
QA Service Level1 (Verified on 04/19/2022)

Sample Information

Sample Taken Date05/23/2023 Sample Unique Key52
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/02/2023
Sample typeVerification A brief description of the samplePSUE 3/4" RHMA-G-SP 0.5% LAS
The quantity of what the sample constitutes4 Bags Of Comb. Agg., 1 Bag Scrap, 1 Bag Hi-Nat From where was the sample collectedManufacturer
First name of sampler or witnessed byVictor Last name of sampler or witnessed byPham
Title of sampler Telephone number of sampler
Laboratory sample identification0289G-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAll American Asphalt-Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0005
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at All American Irwindale Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number106835 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-05-23-52
DIME Test ID: 2023-05-23-52-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2023-09-07

Test Results


Input Type: Measured
Tester's full name: Friday Ofoegbu
Date of test: 06/05/2023
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 975.2 grams
Mass of the pycnometer with water (B): 660.4 grams
Mass of the oven dried sample (before pycnometer) (A): 494.4 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 494.4 grams
Test Sample Preparation: 6% Moisture
Bulk specific gravity: 2.670
Bulk specific gravity (SSD Basis): 2.700
Apparent specific gravity: 2.753
Absorption: 1.1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/7/2023