Summary for Test 2023-05-18-72-6
Test performed: SCAQMD 309-91-Feb93Project Information
| Project Identifiers | Project ID: 994759 DEA: 120T1004 EFIS: 1222000002 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-90,91-0.0-18.0 |
| Award Date | 03/06/2023 |
| Closeout Date | 01/03/2024 |
| Work Description | Treat bridge, overlay with polyester concrete and replace joint seal. |
| Location Description | ROUTE 90 AT ESPERANZA ROAD OVERHEAD AND ON ROUTE 91 FROM CARMENITA ROAD PEDESTRIAN OVERCROSSING TO COAL CANYON ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 04/28/2023) |
Sample Information
| Sample Taken Date | 05/18/2023 | Sample Unique Key | 72 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/22/2023 |
| Sample type | Quality Control | A brief description of the sample | 1 gallon can |
| The quantity of what the sample constitutes | 10 Tankers | From where was the sample collected | Source |
| First name of sampler or witnessed by | Gilberto | Last name of sampler or witnessed by | Gonzalez |
| Title of sampler | Quality Control Manager | Telephone number of sampler | 17076245467 |
| Laboratory sample identification | 943775 | Linked DIME Sample ID | 943775 |
| The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Polyester | Mfg. Lot Number(s) | 1472177 |
|---|---|---|---|
| Batch number | 1472177 | Mix number | 1472177 |
Test Details
DIME Sample ID: 2023-05-18-72
DIME Test ID: 2023-05-18-72-6
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Test Release Date: 2023-07-14
Test Results
Input Type: Measured
Tester's full name: Gilberto Gonzalez
Date of test: 05/30/2023
Diameter of lid: 153.9 mm
Room Temperature: 77 f
Tare weight: no data
Initial weight: 100.092 grams
Weight at 5 minutes: 100.018 grams
Weight at 10 minutes: 99.944 grams
Weight at 15 minutes: 99.85 grams
Weight at 20 minutes: 99.744 grams
Weight at 25 minutes: 99.674 grams
Weight at 30 minutes: 99.607 grams
Final weight: 99.61 grams
Total weight loss: 0.48 grams
Calculated radius of gallon can lid in cm: 7.695 cm
Lid Factor: 53.757 m^2
Volatile emission: 25.911 grams/m^2
General comments (publicly viewable) (Max 1000 characters): Accepted supplier's results.
Test was verified on 7/14/2023 ✔