Summary for Test 2023-06-06-75-4
Test performed: AASHTO T210-15Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/06/2023 | Sample Unique Key | 75 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/05/2023 |
| Sample type | Verification | A brief description of the sample | 1/2" Aggregate |
| The quantity of what the sample constitutes | 4 Bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Allen | Last name of sampler or witnessed by | Oliver |
| Title of sampler | MREA | Telephone number of sampler | |
| Laboratory sample identification | 23-JFMPP-0135 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | SPM-Avenal | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-10-0006 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | L222312A | The fabricator/manufacturer designation for the sample | |
| The plant number | A detailed description of where the material sample was collected | HMA Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-06-06-75
DIME Test ID: 2023-06-06-75-4
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)
Test Release Date: 2023-07-13
Test Results
Which test procedure(s) is/are used?: Procedure A and Procedure B
Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 07/13/2023
Was strict temperature control maintained?: Yes
What type of water was used?: Deminerialized
Height of sediment column: 1.0 in
Clay reading: 6.1 in
Sand reading: 4 in
Durability Index (coarse): 74
Durability Index (fine): 66
General comments (publicly viewable) (Max 1000 characters): Durability Procedure "A" Coarse Aggregate and Procedure "B" Fine Aggregate.
Test was verified on 7/13/2023 ✔