Summary for Test 2023-07-11-18-6
Test performed: AASHTO T324-14Project Information
Project Identifiers | Project ID: 994399 DEA: 09378704 EFIS: 0919000001 |
---|---|
DIST-CO-RTE-PM | 09-MNO-395-55.5/58.2 |
Award Date | 12/22/2022 |
Closeout Date | 12/22/2023 |
Work Description | PARTIAL DEPTH RECYCLE AND HMA (TYPE A). |
Location Description | MONO COUNTY NEAR LEE VINING FROM 0.2 MILE SOUTH OF CEMETERY ROAD TO ROUTE 167 |
QA Service Level | 1 (Verified on 07/31/2023) |
Sample Information
Sample Taken Date | 07/11/2023 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/11/2023 |
Sample type | Department Acceptance | A brief description of the sample | 3/4" HMA-A-SP PG58-34M R15 |
The quantity of what the sample constitutes | 12 Boxes of HMA | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Nicole | Last name of sampler or witnessed by | Berkovatz |
Title of sampler | Granite QC | Telephone number of sampler | |
Laboratory sample identification | PSU-01 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Granite - Lee Vining Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | 13766 |
Test Details
DIME Sample ID: 2023-07-11-18
DIME Test ID: 2023-07-11-18-6
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2023-07-13
Test Results
Input Type: Calculated
Tester's full name: Derek Carrington
Date of test: 07/13/2023
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: 15000
Impression at specified number of passes average: 2.97 mm
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 15000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 15000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 3.16 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 2.78 mm
Stripping Inflection Point (Wheel A): 0
Stripping Inflection Point (Wheel B): 0
General comments (publicly viewable) (Max 1000 characters): PSU-01
Test was verified on 7/13/2023 ✔