Summary for Test 2023-05-22-57-8
Test performed: CTM 214-August 2010Project Information
Project Identifiers | Project ID: 214336 DEA: 07302404 EFIS: 0713000488 |
---|---|
DIST-CO-RTE-PM | 07-VEN-101-37/40 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | PADRE JUAN REHAB |
Location Description | VEN 101 |
QA Service Level | 1 (Verified on 02/26/2021) |
Sample Information
Sample Taken Date | 05/22/2023 | Sample Unique Key | 57 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/23/2023 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | 1 inch Agg |
The quantity of what the sample constitutes | Three 50 pound samples | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Majid | Last name of sampler or witnessed by | fahrtosh |
Title of sampler | Telephone number of sampler | 5624498001 | |
Laboratory sample identification | Linked DIME Sample ID | 2023-05-22-54 | |
The fabricator/manufacturer/facility name | Grimes Rock Inc. | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-56-0032 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | 1 inch minus | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-05-22-57
DIME Test ID: 2023-05-22-57-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2023-07-12
Test Results
What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: Siegfried Mendoza
Date of test: 06/28/2023
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: 5.0 %
Percentage Loss of material retained on ¾ x ½ in. sieve: 5.8 %
Percentage Loss of material retained on ½ x ⅜ in. sieve: 6.9 %
Percentage Loss of material retained on ⅜ in. x #4 sieve: 3.7 %
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 5.7 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/12/2023 ✔