Summary for Test 2023-06-23-38-2
Test performed: AASHTO T176-08Project Information
| Project Identifiers | Project ID: 993608 DEA: 081H8204 EFIS: 0817000138 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-15,138-R21.6,R14.8/R15.1 |
| Award Date | 08/26/2022 |
| Closeout Date | 03/28/2024 |
| Work Description | SIGNAL AND LIGHTING SYSTEM, HMA, JPCP, AND ROADWAY EXCAVATION. |
| Location Description | SAN BERNARDINO COUNTY IN PHELAN ON ROUTE 138 FROM 0.3 MILE WEST OF ROUTE 138/15 SEPARATION TO ROUTE 138/15 SEPARATION AND ON ROUTE 15 SOUTHBOUND EXIT RAMP AT ROUTE 138 |
| QA Service Level | 1 (Verified on 11/16/2022) |
Sample Information
| Sample Taken Date | 06/23/2023 | Sample Unique Key | 38 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/24/2023 |
| Sample type | Department Acceptance | A brief description of the sample | 3/4" HMA-A R15 |
| The quantity of what the sample constitutes | 1 Bag from each bin: 3/4", 1/2", 3/8", & Sand | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Idris | Last name of sampler or witnessed by | Najjar |
| Title of sampler | TE | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vulcan Oro Grande | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-36-0022/91-36-0046/91-36-00137 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Conveyor Belt | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | 224112A ORO SJR |
Test Details
DIME Sample ID: 2023-06-23-38
DIME Test ID: 2023-06-23-38-2
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2023-07-05
Test Results
How many times will the test be run?: 3 Times
Input Type: Calculated
Tester's full name: Maryanna Landaverde
Date of test: 06/28/2023
Sand Equivalent (Test 1): 69
Sand Equivalent (Test 2): 75
Sand Equivalent (Test 3): 73
Sand Equivalent: 73
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/5/2023 ✔