Summary for Test 2023-06-29-2-3
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 214956 DEA: 042K1704 EFIS: 0416000378 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-880,880-15.6/26.5 |
| Award Date | 01/03/2023 |
| Closeout Date | 10/06/2025 |
| Work Description | CONSTRUCT PVMT, JT SEAL, BARRIER, CL RAILING AND BRIDGE REMOVAL. |
| Location Description | ALAMEDA COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 05/08/2020) |
Sample Information
| Sample Taken Date | 06/29/2023 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 06/29/2023 |
| Sample type | Quality Assurance | A brief description of the sample | Bar-Lock Standard Couplers |
| The quantity of what the sample constitutes | 1 lot | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Ryan | Last name of sampler or witnessed by | Parr |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | C&N Reinforcing | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B373-951-23 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC |
| Coupler Manufacturer | Dayton Superior | Intermediate Assembler or Fabricator | |
| Rebar Size | #4 | Coupler Model | Bar-Lock L Series D250L |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | 192700 | Rebar Heat Number(s) | 4129224 |
| Rebar Size 2 | Coupler Unique ID | SL-17-06 |
Test Details
DIME Sample ID: 2023-06-29-2
DIME Test ID: 2023-06-29-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2023-06-30
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 06/30/2023
UTM: 400kip
Temperature: 72.00 f
Halo ID:
| Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | No. 4/13mm | 1 | 0 | 0.2 | 20048 | 100242 | Service Splice | aauvinen |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 6/30/2023 ✔