Summary for Test 2023-06-26-23-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 994753 DEA: 061E8404 EFIS: 0622000104 |
|---|---|
| DIST-CO-RTE-PM | 06--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 05/10/2023) |
Sample Information
| Sample Taken Date | 06/26/2023 | Sample Unique Key | 23 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/27/2023 |
| Sample type | Department Acceptance | A brief description of the sample | 3/4" hma TYPE A |
| The quantity of what the sample constitutes | 10 box HMA | From where was the sample collected | Source |
| First name of sampler or witnessed by | Paul | Last name of sampler or witnessed by | Klinker |
| Title of sampler | Telephone number of sampler | 6615498281 | |
| Laboratory sample identification | L1SL5 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Griffith Edmonston | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 5 | HMA Mix Number | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-06-26-23
DIME Test ID: 2023-06-26-23-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-06-27
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 06/27/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7328.4 grams
Mass of oven-dry sample in air for Sample 1: 2629.4 grams
Mass of container filled with the sample and water for Sample 1: 8935.7 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.573
Theoretical maximum density at 25°C (77°F): 2565.5 kg/m^3
General comments (publicly viewable) (Max 1000 characters): L1SL5
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| 06-1E8404_37014_230626_L1SL5_T209 | 41.18 KB | 06/27/2023 | 2023-06-26-23-1 | Info |
Test was verified on 6/27/2023 ✔