Summary for Test 2023-05-18-94-2
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 993631 DEA: 120S8904 EFIS: 1221000058 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-1-R0.1/R1.0 |
| Award Date | 05/02/2022 |
| Closeout Date | 09/07/2023 |
| Work Description | COLD PLANE AC PAVEMENT AND PLACE RHMA. |
| Location Description | ORANGE COUNTY IN DANA POINT AND SAN JUAN CAPISTRANO FROM ROUTE 5/1 SEPARATION TO SAN JUAN CREEK BRIDGE |
| QA Service Level | 1 (Verified on 03/21/2022) |
Sample Information
| Sample Taken Date | 05/18/2023 | Sample Unique Key | 94 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/18/2023 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 HMA-A | The quantity of what the sample constitutes | HMA, AGG |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Jimmy |
| Last name of sampler or witnessed by | Pham | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 23-0440 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | RJ Noble Orange | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-05-18-94
DIME Test ID: 2023-05-18-94-2
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-06-23
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: David Nguyen
Date of test: 05/23/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7309.2 grams
Mass of oven-dry sample in air for Sample 1: 2523.8 grams
Mass of container filled with the sample and water for Sample 1: 8837.4 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.535
Theoretical maximum density at 25°C (77°F): 157.8 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| 2023TMSG-SP-0016 | 104.34 KB | 06/23/2023 | 2023-05-18-94-2 | Info |
Test was verified on 6/23/2023 ✔