Summary for Test 2016-11-10-4-1
Test performed: ASTM C39-17aProject Information
| Project Identifiers | Project ID: 210569 DEA: 083555V4 EFIS: 0814000086 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-15-42.5/46.0 |
| Award Date | 11/05/2015 |
| Closeout Date | 01/18/2022 |
| Work Description | WIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR. |
| Location Description | SAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 10/15/2015) |
Sample Information
| Sample Taken Date | 11/10/2016 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/15/2016 | Sample type | Quality Control |
| A brief description of the sample | 6X12 | The quantity of what the sample constitutes | 2 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | DARREN |
| Last name of sampler or witnessed by | HOPPER | Title of sampler | ASR |
| Telephone number of sampler | Unknown | Laboratory sample identification | 934-09 |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | ROBERTSONS MIX |
| Transportation Laboratory (TL) Number | 180609 | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | VICTORVILLE SEP AND OH BR WIDEN AND NEW | Structure name | FOOTING FOR RIGHT AND NEW BENT 4 |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | SC675B38 |
|---|---|---|---|
| The truck number from where the sample was collected | 1728 | The batch plant ticket number from where the sample was collected | 1086876 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | PUMP TREMIE | Where the material sample would have been placed if not sampled | Unknown |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2016-11-10-4
DIME Test ID: 2016-11-10-4-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-01-10
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 12/08/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Maximum load on cylinder 1: 142030 lb
Maximum load on cylinder 2: 145070 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength of cylinder 1: 5056.2 psi
Compressive strength of cylinder 2: 5164.5 psi
Compressive strength (to nearest 10 psi): 5110 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/3/2017 ✔