Summary for Test 2023-06-13-2-1

Test performed: ASTM A370-20

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date06/13/2023 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing06/15/2023 Sample typeQuality Assurance
A brief description of the sampleASTM A536 Grade 80-55-06 Ductile Iron Casting The quantity of what the sample constitutes879 Anchor Ring / 870 Anchor Head
From where was the sample collectedManufacturer First name of sampler or witnessed byArthur
Last name of sampler or witnessed byPeterson Title of samplerAssociate Steel Inspector
Telephone number of sampler7073428602 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGlobe Iron Foundry, Inc.
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL110-055-23
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)11623
Part Number (s) Recessed Anchor Head and Anchor Head Ring Material SpecificationA536
Grades80-55-06 Metal Foundry Manufacturer (Mill)Globe Iron Castings
Prestressing ManufacturerStresssteel PT Systems

Test Details

DIME Sample ID: 2023-06-13-2
DIME Test ID: 2023-06-13-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2023-06-23

Test Results


Number of Samples: 4
Input Type: Calculated
Tester's full name: aauvinen
Date of test: 06/20/2023
UTM: 67kip
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1116230.5010.197145952210302710.1aauvinen
2116230.50.196355960010347210.7aauvinen
3116230.50.196355971610360710.4aauvinen
4116230.50.19635601131046699.6aauvinen

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 6/23/2023