Summary for Test 2016-12-14-7-4
Test performed: ASTM D2628-91-re11-lowProject Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 12/14/2016 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/20/2016 |
Sample type | Quality Assurance | A brief description of the sample | Joint Seal |
The quantity of what the sample constitutes | 550 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Simon |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | D S Brown | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM2 - Type B Elastomeric Joint Seal | Mfg. Lot Number(s) | 0816443 |
---|---|---|---|
Manufacturer(s) | D S Brown | Temperature | 72 |
Humidity | 50 | Comments | Unknown |
Joint Seal Size | 3.5" |
Test Details
DIME Sample ID: 2016-12-14-7
DIME Test ID: 2016-12-14-7-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D2628-91-re11-low: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements (Low Temp Recovery)
Test Release Date: 2017-01-13
Test Results
Input Type: Measured
Tester's full name: Brian Ewing
Date of test: 12/22/2016
Temperature: 72 f
Humidity: 50 %
Low Temp Recovery (22 hrs at -20F) Size Before (Height of Contact Face ): 3.5 in
Low Temp Recovery (22 hrs at -20F) Size After (Recovered Contact Face ): 3.357 in
Percent Recovery (Low Temp): 96 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/6/2017 ✔