Summary for Test 2023-05-12-82-1

Test performed: CTM 523-May 2020

Project Information

Project IdentifiersProject ID: 6585
DEA: 120H0014
DIST-CO-RTE-PM12-ORA-39-9.1
Award Date08/16/2006
Closeout Date07/28/2010
Work DescriptionMODIFY SIGNAL AND EXTEND LEFT TURN
Location DescriptionIN ORANGE COUNTY IN HUNTINGTONBEACH AND WESTMINSTER AT EDINGERAVENUE
QA Service Level1 (Verified on 07/28/2010)

Sample Information

Sample Taken Date05/12/2023 Sample Unique Key82
Date that the sample was received by the laboratory/organization performing the testing05/13/2023 Sample typeQuality Assurance
A brief description of the sampleconcerete beams The quantity of what the sample constitutes3 beams
From where was the sample collectedJob Site First name of sampler or witnessed byJohnny Cuong
Last name of sampler or witnessed byDo Title of sampler
Telephone number of sampler7143066148 Laboratory sample identification23-0160
Linked DIME Sample ID The fabricator/manufacturer/facility nameRobertsons-Anaheim
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberLB060008
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected000
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedAT THE JOB SITE Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-05-12-82
DIME Test ID: 2023-05-12-82-1
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2023-06-10

Test Results


Number of specimens: 2
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: Johnny Do
Date of test: 06/09/2023
Identification number: 23-0160
Width of specimen: 6.0 inch
Width of specimen 2: 6.0 inch
Depth of specimen: 6.0 inch
Depth of specimen 2: 6.0 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Maximum load applied: 7835 lb
Maximum load applied 2: 8032 lb
Curing history and apparent moisture condition of the specimen: lime water bath
If specimen was capped, ground or if leather shims were used: 0
Defects in specimen: 0
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Modulus of rupture: 680 psi
Modulus of rupture 2: 710 psi
Modulus of rupture average: 700 psi
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
23-0160pdf270.52 KB06/10/20232023-05-12-82-1   Info

Test was verified on 6/10/2023 ✔