Summary for Test 2023-04-11-87-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 2720
DEA: 050N7204
EFIS: 0500000227
MINOR: 05A1245
DIST-CO-RTE-PM05---
Award DateNot set
Closeout Date03/18/2020
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 11/08/2019)

Sample Information

Sample Taken Date04/11/2023 Sample Unique Key87
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/11/2023
Sample typeQuality Assurance A brief description of the sample1 x 4 PCC Aggregate
The quantity of what the sample constitutes9 CY From where was the sample collectedSupplier
First name of sampler or witnessed byDorell Last name of sampler or witnessed byHarper
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCEMEX Santa Barbara Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number1614705 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-04-11-87
DIME Test ID: 2023-04-11-87-1
Testing Lab: CT D05 - Carpinteria Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2023-06-09

Test Results


What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Jesse Gomez
Date of test: 04/11/2023
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 91 %
Cumulative percent passing the 3/4 in. sieve: 72 %
Cumulative percent passing the 1/2 in. sieve: 48 %
Cumulative percent passing the 3/8 in. sieve: 33 %
Cumulative percent passing the #4 sieve: 4 %
Cumulative percent passing the #8 sieve: 1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/9/2023