Summary for Test 2023-06-01-9-1

Test performed: ASTM A370-20

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date06/01/2023 Sample Unique Key9
Date that the sample was received by the laboratory/organization performing the testing06/01/2023 Sample typeAuthorization
A brief description of the sample19 strand anchor head The quantity of what the sample constitutesOne anchor head
From where was the sample collectedSupplier First name of sampler or witnessed byDavid
Last name of sampler or witnessed byMurray Title of sampler
Telephone number of sampler9166395549 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameFarrar Corporation
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)I212
Part Number (s)02AH0038 Material SpecificationA536
Grades80-55-06 Metal Foundry Manufacturer (Mill)Farrar Corporation
Prestressing ManufacturerSumiden

Test Details

DIME Sample ID: 2023-06-01-9
DIME Test ID: 2023-06-01-9-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2023-07-12

Test Results


Number of Samples: 2
Input Type: Calculated
Tester's full name: aauvinen
Date of test: 06/06/2023
UTM: 67kip
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
10.2520.04988648401081186.5aauvinen
20.2510.04948632011073307.4aauvinen

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 7/12/2023 ✔