Summary for Test 2023-06-01-10-2

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 993742
DEA: 07321804
EFIS: 0716000052
DIST-CO-RTE-PM07-LA-405-7.0/12.9
Award Date07/06/2022
Closeout Date03/13/2025
Work DescriptionPLACE MINOR CONCRETE AND HOT MIX ASPHALT.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR LONG BEACH, CARSON AND LOS ANGELES AT VARIOUS LOCATIONS FROM 0.1 MILE NORTH OF ROUTE 710 TO ROUTE 110/405 SEPARATION
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date06/01/2023 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/01/2023
Sample typeDepartment Acceptance A brief description of the sampleAggregate Base
The quantity of what the sample constitutes143 CY From where was the sample collectedJob Site
First name of sampler or witnessed byJacinto Last name of sampler or witnessed byVillanueva
Title of samplerTEC Telephone number of sampler8182096574
Laboratory sample identification23-0768 Linked DIME Sample ID
The fabricator/manufacturer/facility nameWestcoast Public Works Construction Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleAggregate Base
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedfrom various location at Aggregate Base
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2023-06-01-10
DIME Test ID: 2023-06-01-10-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-06-01

Test Results


Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Jacinto Villanueva
Date of test: 06/01/2023
Gage No.: 60247
Test No.: 1
Nuclear By: jacinto villanueva
Non-Bias Plan No.: 5
Depth: 5
Material No.: on site
Material Type: aggregate base
Impact By: jacinto villanueva
Standard Count Density: 2119 g/cc
Count or Density 1: 2.07 g/cc
Count or Density 2: 2.05 g/cc
Count or Density 3: 2.06 g/cc
Standard Count Moisture: 641 g/cc
Moisture Count 1: 0.19 g/cc
Moisture Count 2: 0.15 g/cc
Moisture Count 3: 0.18 g/cc
Sum of Count or Density: 6.18 g/cc
Average of Count or Density: 2.06 g/cc
Sum of Moisture Count: 0.52 g/cc
Average of Moisture Count: 0.17 g/cc
Calculated Percent Relative Compaction: 94.1 %
Reported Percent Relative Compaction: 94 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/1/2023