Summary for Test 2016-12-21-3-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211864 DEA: 042L8104 EFIS: 0412000177 MINOR: 04A4925 |
---|---|
DIST-CO-RTE-PM | 04-SF-1,280-3.85, 2.58 |
Award Date | Not set |
Closeout Date | 07/05/2023 |
Work Description | Cold plane and resurface ramp and install vehicle speed feedback sign. |
Location Description | ON ROUTE 1 BETWEEN JUDAH STREET AND IRVING STREET AND ON ROUTE 280 AT SAN JOSE AVENUE OFF-RAMP |
QA Service Level | 1 (Verified on 11/01/2016) |
Sample Information
Sample Taken Date | 12/21/2016 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/21/2016 |
Sample type | Quality Assurance | A brief description of the sample | Resistance Butt Welded Hoops |
The quantity of what the sample constitutes | 24 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | James | Last name of sampler or witnessed by | Doe |
Title of sampler | CALTRANS METS QA INSPECTOR | Telephone number of sampler | (510) 918-4918 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Mission City Rebar | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B358-131-16 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | PL16101722 |
Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 4 |
Diameter of Hoop | 2'-2" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Nucor |
Welding Company | Mission City Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2016-12-21-3
DIME Test ID: 2016-12-21-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-01-04
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 12/28/2016
UTM: 75KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2 | 1 | #4/13mm | 0.2 | 19197 | 95990 | necking okay | Fred |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 12/28/2016 ✔