Summary for Test 2023-05-24-8-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 215741
DEA: 01366004
EFIS: 0100000127
DIST-CO-RTE-PM01-HUM-101-80.0/84.0
Award Date12/29/2022
Closeout DateNot set
Work DescriptionIndianola Cutoff UC
Location DescriptionHUMBOLDT COUNTY NEAR EUREKA FROM EUREKA SLOUGH BRIDGE TO BAYSIDE CUTOFF
QA Service Level1 (Verified on 05/17/2021)

Sample Information

Sample Taken Date05/24/2023 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/24/2023
Sample typeQuality Assurance A brief description of the sample#5 bar 1'-6.5" diameter
The quantity of what the sample constitutes150 From where was the sample collectedFabricator
First name of sampler or witnessed bySherri Last name of sampler or witnessed byBrannon
Title of samplerCT METS QA INSPECTOR Telephone number of sampler9168266371
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameConco Companies Benicia Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB22-195-23 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)4126773
Hoop Manufacturer Lot Number(s)20 Material Standard CodeASTM A706
Material Grade60 Rebar Size#5
Diameter of Hoop1'-6.5" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyConco Companies Benicia Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2023-05-24-8
DIME Test ID: 2023-05-24-8-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2023-05-30

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 05/25/2023
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12H205/16mm0.3130998.8499996Ok Neckingaauvinen

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 5/30/2023