Summary for Test 2023-04-18-54-6

Test performed: CTM 206-October 2011

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/18/2023 Sample Unique Key54
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing04/20/2023
Sample typeAggregate Prequalification Program A brief description of the sample3/8” Rock
The quantity of what the sample constitutes50 tons From where was the sample collectedSource
First name of sampler or witnessed byMatt Last name of sampler or witnessed byLincoln
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID2023-04-18-36
The fabricator/manufacturer/facility nameChandler Aggregates Inc. Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0011
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBunker pull from yard truck
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-04-18-54
DIME Test ID: 2023-04-18-54-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 206-October 2011: Method of Test for Specific Gravity and Absorption of Coarse Aggregate
Test Release Date: 2023-05-25

Test Results


How will the aggregate be used?: aggregate base
Input Type: Calculated
Tester's full name: Larry Diaz
Date of test: 05/04/2023
% Water Absorbed: 1.5 %
Bulk Oven Dried Specific Gravity: 2.62
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/25/2023