Summary for Test 2023-05-12-63-1
Test performed: AASHTO T27-14Project Information
| Project Identifiers | Project ID: 994120 DEA: 040J6314 EFIS: 0421000252 |
|---|---|
| DIST-CO-RTE-PM | 04-SOL-12-21.2/22.6 |
| Award Date | 09/27/2022 |
| Closeout Date | 01/09/2025 |
| Work Description | ROADWAY RESURFACING, INSTALL DRAINAGE SYSTEM, MIDWEST GUARDRAIL SYSTEM |
| Location Description | SOLANO COUNTY NEAR RIO VISTA FROM MCCLOSKY ROAD TO 0.1 MILE WEST OF AZEVEDO ROAD |
| QA Service Level | 1 (Verified on 09/13/2022) |
Sample Information
| Sample Taken Date | 05/12/2023 | Sample Unique Key | 63 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/12/2023 |
| Sample type | Quality Assurance | A brief description of the sample | 1/2 HMA Type A |
| The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Trenton | Last name of sampler or witnessed by | Cross |
| Title of sampler | QC Technician | Telephone number of sampler | |
| Laboratory sample identification | Con_23_438 | Linked DIME Sample ID | 2023-05-12-59 |
| The fabricator/manufacturer/facility name | Teichert Vernalis | Transportation Laboratory (TL) Number | C727234 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | JMF | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-39-0041 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | 1/2 HMA Type A | The fabricator/manufacturer designation for the sample | Drum Plant |
| The plant number | A detailed description of where the material sample was collected | coldfeed | |
| Where the material sample would have been placed if not sampled | JMF | Primary Aggregate Nominal Size | 1/2 inch |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | 30240442412V |
Test Details
DIME Sample ID: 2023-05-12-63
DIME Test ID: 2023-05-12-63-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2023-05-18
Test Results
What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Calculated
Tester's full name: Augusto Rios
Date of test: 05/16/2023
| Cumulative Percent Passing | ||||||
|---|---|---|---|---|---|---|
| % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 95 % | ||||||
| 82 % | ||||||
| 54 % | ||||||
| 38 % | ||||||
| 23 % | ||||||
| 15 % | ||||||
| 11 % | ||||||
| 6 % | ||||||
| 4 % | ||||||
General comments (publicly viewable) (Max 1000 characters): JMF
Test was verified on 5/18/2023 ✔