Summary for Test 2023-05-12-51-2
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 215677 DEA: 044G0804 EFIS: 0412000332 COOP: 042676 |
|---|---|
| DIST-CO-RTE-PM | 04-SOL-80-R10.4/30.2 |
| Award Date | 01/18/2022 |
| Closeout Date | Not set |
| Work Description | Highway widening, overhead signs, and electronic toll system. |
| Location Description | In Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing. |
| QA Service Level | 1 (Verified on 04/11/2022) |
Sample Information
| Sample Taken Date | 05/12/2023 | Sample Unique Key | 51 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/12/2023 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4 Recycled AB |
| The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Augusto | Last name of sampler or witnessed by | Rios |
| Title of sampler | QA Technician | Telephone number of sampler | 9097710834 |
| Laboratory sample identification | Con_23_421 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | O.C. Jones & Sons | Transportation Laboratory (TL) Number | C422-324 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 00-00-0004 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | 3/4 Recycled Class 2 AB | The fabricator/manufacturer designation for the sample | M-Line EB/WB 80 Ulatis OC to Allison UC |
| The plant number | A detailed description of where the material sample was collected | stockpile 95510 | |
| Where the material sample would have been placed if not sampled | Roadway | Primary Aggregate Nominal Size | 3/4 inch |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-05-12-51
DIME Test ID: 2023-05-12-51-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2023-05-16
Test Results
Number of tests: 1
Input Type: Measured
Tester's full name: Augusto Rios
Date of test: 05/15/2023
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 10.7
Sand reading (test 1): 3.1
Sand equivalent (test 1): 29
Sand equivalent before temperature correction: 29
Sand equivalent after temperature correction: 29
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/16/2023 ✔