Summary for Test 2023-05-15-18-2
Test performed: CTM 227-December 2014Project Information
Project Identifiers | Project ID: 215396 DEA: 042K8404 EFIS: 0417000031 |
---|---|
DIST-CO-RTE-PM | 04-SOL-29,80-0.0,0.8/1.6 |
Award Date | 03/26/2021 |
Closeout Date | 02/16/2024 |
Work Description | HMA, STRUCTURAL CONCRETE, CIDH PILING AND REBAR. |
Location Description | SOLANO COUNTY IN VALLEJO AT ROUTE 80/29 SEPARATION AND ON ROUTE 80 FROM 0.2 MILE NORTH OF CARQUINEZ BRIDGE TOLL PLAZA TO 0.3 MILE SOUTH OF MAGAZINE STREET OVERCROSSING |
QA Service Level | 1 (Verified on 01/25/2021) |
Sample Information
Sample Taken Date | 05/15/2023 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/15/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1" X No 4 |
The quantity of what the sample constitutes | 1 Bag | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Plant QC | Last name of sampler or witnessed by | Plant QC |
Title of sampler | QC Technician | Telephone number of sampler | |
Laboratory sample identification | Con_23_418 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Central Concrete Martinez | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 23-0259 | |
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Hanson-Pier 94 CT |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Coarse Aggregate | The fabricator/manufacturer designation for the sample | Batch |
The plant number | A detailed description of where the material sample was collected | belt cut | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | D101C5RS | Lot number | |
Sublot number | Aggregate Mix Number | D101C5RS |
Test Details
DIME Sample ID: 2023-05-15-18
DIME Test ID: 2023-05-15-18-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2023-05-16
Test Results
Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Augusto Rios
Date of test: 05/15/2023
Top sediment column reading (single primary size): 0.6 in
Cleanness value (single primary size): 84
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/16/2023 ✔