Summary for Test 2023-05-09-67-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 215396
DEA: 042K8404
EFIS: 0417000031
DIST-CO-RTE-PM04-SOL-29,80-0.0,0.8/1.6
Award Date03/26/2021
Closeout Date02/16/2024
Work DescriptionHMA, STRUCTURAL CONCRETE, CIDH PILING AND REBAR.
Location DescriptionSOLANO COUNTY IN VALLEJO AT ROUTE 80/29 SEPARATION AND ON ROUTE 80 FROM 0.2 MILE NORTH OF CARQUINEZ BRIDGE TOLL PLAZA TO 0.3 MILE SOUTH OF MAGAZINE STREET OVERCROSSING
QA Service Level1 (Verified on 01/25/2021)

Sample Information

Sample Taken Date05/09/2023 Sample Unique Key67
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/09/2023
Sample typeQuality Assurance A brief description of the sample1" x No 4 Aggregate
The quantity of what the sample constitutes1 bag From where was the sample collectedManufacturer
First name of sampler or witnessed byPlant QC Last name of sampler or witnessed byPlant QC
Title of samplerQC Technician Telephone number of sampler
Laboratory sample identificationCon_23_394 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCentral Concrete Martinez Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0010
The fabricator's/manufacturer's product name for the sampleCoarse Aggregate The fabricator/manufacturer designation for the sampleBatch
The plant number A detailed description of where the material sample was collectedbelt cut
Where the material sample would have been placed if not sampledbarrier Primary Aggregate Nominal Size1 inch
The concrete mix design numberD20115EA Lot number
Sublot number Aggregate Mix NumberD20115EA

Test Details

DIME Sample ID: 2023-05-09-67
DIME Test ID: 2023-05-09-67-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2023-05-16

Test Results


What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Augusto Rios
Date of test: 05/10/2023
Cumulative Mass RetainedCumulative Percent Passing
7280 grams
0 grams100 %
0 grams100 %
320 grams96 %
2590 grams64 %
3935 grams46 %
6515 grams11 %
7110 grams2 %
7190 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/16/2023