Summary for Test 2023-03-27-59-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993301
DEA: 060U2804
EFIS: 0615000293
DIST-CO-RTE-PM06-TUL-245-1.4,4.2
Award Date01/03/2022
Closeout Date05/09/2025
Work DescriptionPRECAST PRESTRESSED CONCRETE BOX GIRDER AND SLAB, BRIDGE REMOVAL.
Location DescriptionTULARE COUNTY NEAR WOODLAKE AT YOKOHL CREEK BRIDGE AND AT KAWEAH RIVER BRIDGE
QA Service Level1 (Verified on 10/11/2021)

Sample Information

Sample Taken Date03/27/2023 Sample Unique Key59
Date that the sample was received by the laboratory/organization performing the testing03/27/2023 Sample typeQuality Assurance
A brief description of the sample3/4" HMA The quantity of what the sample constitutes326 Tons
From where was the sample collectedSupplier First name of sampler or witnessed byJason
Last name of sampler or witnessed byRuiz Title of samplerConsultant Tester
Telephone number of sampler5592890420 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namePorterville Rock and Recycle PAI
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name Tul 245 Kaweah- Yokohl Bridges Wood Land
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number6 HMA Mix Number22J026
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2023-03-27-59
DIME Test ID: 2023-03-27-59-1
Testing Lab: CT D06 - Visalia Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-05-15

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Jason Ruiz
Date of test: 03/27/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2128.6 g
Mass Loss: 130.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.39 %
Moisture Content: 0.43 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.18 %
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-0U2804_37043__230327_SA_L1SL6-T308pdf167.43 KB05/15/20232023-03-27-59-1   Info

Test was verified on 5/15/2023 ✔