Summary for Test 2023-04-28-1-7

Test performed: CTM 523-May 2020

Project Information

Project IdentifiersProject ID: 215180
DEA: 060Q9204
EFIS: 0614000010
COOP: 061764
DIST-CO-RTE-PM06-KER-99-10.4/21.2
Award Date12/08/2020
Closeout Date11/03/2025
Work DescriptionCONSTRUCT CRCP AND HMA (TYPE A) PAVEMENT.
Location DescriptionKERN COUNTY IN AND NEAR BAKERSFIELD FROM 0.4 MILE SOUTH OF OLD US 99 OVERCROSSING TO 0.1 MILE NORTH OF WHITE LANE OVERCROSSING
QA Service Level1 (Verified on 09/14/2020)

Sample Information

Sample Taken Date04/28/2023 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing04/28/2023 Sample typeDepartment Acceptance
A brief description of the sampleCRCP The quantity of what the sample constitutes280 CY load 28
From where was the sample collectedSource First name of sampler or witnessed byJames
Last name of sampler or witnessed byWatson Title of sampler
Telephone number of sampler6615498281 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameHwy 223 off ramp sb 99
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberG3-21-PCC-263
The truck number from where the sample was collected2 The batch plant ticket number from where the sample was collected128
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-04-28-1
DIME Test ID: 2023-04-28-1-7
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2023-05-12

Test Results


Number of specimens: 3
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Jason Ruiz
Date of test: 05/12/2023
Identification number: 3
Width of specimen: 6.0 inch
Width of specimen 2: 6.1 inch
Width of specimen 3: 6.0 inch
Depth of specimen: 6.1 inch
Depth of specimen 2: 6.2 inch
Depth of specimen 3: 6.2 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 7640 lb
Maximum load applied 2: 7380 lb
Maximum load applied 3: 7930 lb
Curing history and apparent moisture condition of the specimen: Good and Field Curing Beams
If specimen was capped, ground or if leather shims were used: Leather shims were used
Defects in specimen: 0
Age of specimen: 14 days
Age of specimen in hours: 0 hours
Modulus of rupture: 620 psi
Modulus of rupture 2: 580 psi
Modulus of rupture 3: 630 psi
Modulus of rupture average: 610 psi
General comments (publicly viewable) (Max 1000 characters): Field curing beams

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-0Q9204_37085_230427_14D_03pdf193.02 KB05/12/20232023-04-28-1-7   Info

Test was verified on 5/12/2023 ✔