Summary for Test 2023-04-20-72-1
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 994804 DEA: 021J8004 EFIS: 0220000130 |
---|---|
DIST-CO-RTE-PM | 02-TEH-36-81.68/81.3 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Bike/Ped Pathway |
Location Description | Mineral |
QA Service Level | 1 (Verified on 10/24/2024) |
Sample Information
Sample Taken Date | 04/20/2023 | Sample Unique Key | 72 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/20/2023 |
Sample type | Preliminary | A brief description of the sample | Soil for culvert recommendation, C-1 |
The quantity of what the sample constitutes | Culvert Recommendation C-1 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Steiner |
Title of sampler | AAME | Telephone number of sampler | |
Laboratory sample identification | D79222 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | In Situ | Transportation Laboratory (TL) Number | 895817 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | DI at 02-TEH-36-82.60, 0.0-0.5 foot | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-04-20-72
DIME Test ID: 2023-04-20-72-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2023-05-11
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 04/27/2023
Minimum soil resistance of the lab measurement: 7900 Ohms
Soil sample temperature: 18.9 C
Soil box constant: 1
pH of soil: 5.71
Minimum soil resistance corrected to 15.5: 8571.5 Ohm-cm
Minimum soil resistivity at 15.5: 8572 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=5.71,
ρ=8572Ω∙cm
Test was verified on 5/11/2023 ✔