Summary for Test 2023-05-08-17-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994142 DEA: 044J9504 EFIS: 0416000026 |
---|---|
DIST-CO-RTE-PM | 04-CC-4-R30.8/R40.4 |
Award Date | 09/22/2022 |
Closeout Date | 08/21/2023 |
Work Description | ROADWAY EXCAVATION, TEMPORARY BARRIER, AND HMA PAVING AT MVPS. |
Location Description | CONTRA COSTA COUNTY ON ROUTE 4 AT VARIOUS LOCATIONS FROM 0.4 MILE EAST OF ROUTE 160/4 SEPARATION TO HOFFMAN LANE |
QA Service Level | 1 (Verified on 08/08/2022) |
Sample Information
Sample Taken Date | 05/08/2023 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/08/2023 |
Sample type | Quality Assurance | A brief description of the sample | RAP Aggregate for HMA |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Gray |
Title of sampler | QC Technician | Telephone number of sampler | |
Laboratory sample identification | Con_23_380 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | County Asphalt | Transportation Laboratory (TL) Number | C911357 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | 1 |
Sublot number | 1 | HMA Mix Number | L210223WMA |
Test Details
DIME Sample ID: 2023-05-08-17
DIME Test ID: 2023-05-08-17-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-05-10
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Augusto Rios
Date of test: 05/08/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 3,054.3 g
Mass of the specimen and specimen basket assembly prior to ignition: 4,737.6 g
Mass of HMA Sample prior to ignition: 1,683.3 g
Mass Loss: 105.6 g
Mass of aggregate remaining after ignition: 1,577.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.19 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 6.08 %
General comments (publicly viewable) (Max 1000 characters): RAP Burn
Test was verified on 5/10/2023 ✔