Summary for Test 2023-04-05-38-5
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 994678 DEA: 020J7704 EFIS: 0219000158 |
---|---|
DIST-CO-RTE-PM | 02--299-21.6/22.6 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Construct turnouts in Trinity County at and near del Loma from 1.8 miles east of Big Mountain Road to 0.6 mile west of Big French Creek Road. |
Location Description | Not set |
QA Service Level | 1 (Verified on 08/09/2023) |
Sample Information
Sample Taken Date | 04/05/2023 | Sample Unique Key | 38 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/05/2023 |
Sample type | Preliminary | A brief description of the sample | Soil for structural section recommendation |
The quantity of what the sample constitutes | Structural Section Recommendation | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Steiner |
Title of sampler | AAME | Telephone number of sampler | |
Laboratory sample identification | D79205 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | In Situ | Transportation Laboratory (TL) Number | 895803 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-TRI-299-21.92, Rt shoulder, 0.5-1.5 feet | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-04-05-38
DIME Test ID: 2023-04-05-38-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2023-05-09
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 04/26/2023
Minimum soil resistance of the lab measurement: 5700 Ohms
Soil sample temperature: 17.9 C
Soil box constant: 1
pH of soil: 6.80
Minimum soil resistance corrected to 15.5: 6042.00 Ohm-cm
Minimum soil resistivity at 15.5: 6042 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=6.80,
ρ=6042Ω∙cm
Test was verified on 5/9/2023 ✔