Summary for Test 2023-04-18-95-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214986
DEA: 041J9704
EFIS: 0414000404
DIST-CO-RTE-PM04-SCL-17-2.8/13.94
Award Date04/30/2021
Closeout Date10/06/2025
Work DescriptionPAVING WITH RHMA, COLD PLANE AC, AND INSTALL CULVERT.
Location DescriptionSANTA CLARA COUNTY IN AND NEAR LOS GATOS, CAMPBELL AND SAN JOSE FROM HEBARD ROAD TO ROUTE 17/280 SEPARATION
QA Service Level1 (Verified on 10/19/2020)

Sample Information

Sample Taken Date04/18/2023 Sample Unique Key95
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/18/2023
Sample typeQuality Assurance A brief description of the sample3/4 RHMA-G
The quantity of what the sample constitutes788.56 Tons From where was the sample collectedManufacturer
First name of sampler or witnessed byJerrod Last name of sampler or witnessed byNaval
Title of sampler Telephone number of sampler
Laboratory sample identificationSJ-041823-OC3 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Rock Wilson Aromas Batch Transportation Laboratory (TL) NumberC927716
Inspector Lot Number from the Transportation Laboratory (TL) Form Lot 1 sublot 103 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number1
Sublot number103 HMA Mix Number917
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2023-04-18-95
DIME Test ID: 2023-04-18-95-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-02-12

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Fernando Vega
Date of test: 04/18/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2147.4 g
Mass Loss: 175.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.19 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.08 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 7.90 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/12/2024