Summary for Test 2022-11-02-62-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 215348
DEA: 060U4204
EFIS: 0616000004
DIST-CO-RTE-PM06-FRE-99-R4.9/11.6
Award Date02/25/2021
Closeout Date12/02/2025
Work DescriptionCONSTRUCT CRCP, PLACE HMA, AND ROADWAY EXCAVATION.
Location DescriptionFRESNO COUNTY IN AND NEAR SELMA AND FOWLER FROM MCCALL AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF MERCED STREET UNDERCROSSING
QA Service Level1 (Verified on 12/07/2020)

Sample Information

Sample Taken Date11/02/2022 Sample Unique Key62
Date that the sample was received by the laboratory/organization performing the testing11/03/2022 Sample typeQuality Control
A brief description of the sample4x8 cylinders The quantity of what the sample constitutes5
From where was the sample collectedJob Site First name of sampler or witnessed byAlvaro
Last name of sampler or witnessed byPineda Title of samplerQC Field Technician
Telephone number of samplerUnknown Laboratory sample identificationSet 1
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameJob Site
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifier00-0000 Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberG3-22-BAR-318
The truck number from where the sample was collectedLoad 2 The batch plant ticket number from where the sample was collected0
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleSet 1
A detailed description of where the material sample was collectedOutside Shoulder and Barrier Wall Footing, STA 398-00 Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2022-11-02-62
DIME Test ID: 2022-11-02-62-2
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-05-08

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Mike Kaus
Date of test: 11/30/2022
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 53280 lb
Maximum load on cylinder 2: 51440 lb
Maximum load on cylinder 3: 50330 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 4110 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/8/2023 ✔