Summary for Test 2023-05-03-39-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 215677
DEA: 044G0804
EFIS: 0412000332
COOP: 042676
DIST-CO-RTE-PM04-SOL-80-R10.4/30.2
Award Date01/18/2022
Closeout DateNot set
Work DescriptionHighway widening, overhead signs, and electronic toll system.
Location DescriptionIn Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
QA Service Level1 (Verified on 04/11/2022)

Sample Information

Sample Taken Date05/03/2023 Sample Unique Key39
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/03/2023
Sample typeQuality Assurance A brief description of the sampleClass 2 AB
The quantity of what the sample constitutes2 Bags From where was the sample collectedJob Site
First name of sampler or witnessed byNick Last name of sampler or witnessed byHall
Title of samplerQA Technician Telephone number of sampler7072999133
Laboratory sample identificationCon_23_369 Linked DIME Sample ID
The fabricator/manufacturer/facility nameOC Jones & Sons Transportation Laboratory (TL) NumberC727221
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)00-00-0004
The fabricator's/manufacturer's product name for the sampleClass 2 AB The fabricator/manufacturer designation for the sampleRoadway
The plant number A detailed description of where the material sample was collectedRoadway Sta91900-92900
Where the material sample would have been placed if not sampledRoadway Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-05-03-39
DIME Test ID: 2023-05-03-39-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2023-05-05

Test Results


Number of tests: 1
Input Type: Measured
Tester's full name: Augusto Rios
Date of test: 05/04/2023
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 6.1
Sand reading (test 1): 3.3
Sand equivalent (test 1): 55
Sand equivalent before temperature correction: 55
Sand equivalent after temperature correction: 55
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/5/2023