Summary for Test 2023-04-04-44-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 993429
DEA: 07324804
EFIS: 0716000078
DIST-CO-RTE-PM07-LA-57-5.0
Award Date04/07/2022
Closeout Date09/24/2024
Work DescriptionCONSTRUCT MAINTENANCE VEHICLE PULLOUTS AND BIOFILTRATION SWALE.
Location DescriptionLOS ANGELES COUNTY IN DIAMOND BAR AT SOUTHBOUND ON AND OFF RAMP TO SUNSET CROSSING ROAD
QA Service Level1 (Verified on 12/06/2021)

Sample Information

Sample Taken Date04/04/2023 Sample Unique Key44
Date that the sample was received by the laboratory/organization performing the testing04/04/2023 Sample typeDepartment Acceptance
A brief description of the sampleSoil for structure backfill. The quantity of what the sample constitutes17 yd2
From where was the sample collectedJob Site First name of sampler or witnessed byRosauro
Last name of sampler or witnessed byNogoy Title of samplerTEC
Telephone number of sampler2137939321 Laboratory sample identification23-0352
Linked DIME Sample ID The fabricator/manufacturer/facility nameN/A
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleStructural Backfill
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedFrom various locations at backfill
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2023-04-04-44
DIME Test ID: 2023-04-04-44-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-05-05

Test Results


Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Rosauro Nogoy
Date of test: 04/04/2023
Gage No.: 60202
Test No.: no data
Nuclear By: Rosauro Nogoy
Non-Bias Plan No.: 2
Depth: 12 in
Material No.: Imported Material
Material Type: Structural Backfill
Impact By: Rosauro Nogoy
Standard Count Density: 2332 g/cc
Count or Density 1: 2.12 g/cc
Count or Density 2: 2.15 g/cc
Count or Density 3: 2.14 g/cc
Standard Count Moisture: 628 g/cc
Moisture Count 1: 0.18 g/cc
Moisture Count 2: 0.2 g/cc
Moisture Count 3: 0.2 g/cc
Sum of Count or Density: 6.41 g/cc
Average of Count or Density: 2.14 g/cc
Sum of Moisture Count: 0.58 g/cc
Average of Moisture Count: 0.19 g/cc
Calculated Percent Relative Compaction: 95.4 %
Reported Percent Relative Compaction: 95 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/5/2023 ✔