Summary for Test 2023-04-24-60-2

Test performed: ASTM D5329-16

Project Information

Project IdentifiersProject ID: 993508
DEA: 070W1104
EFIS: 0721000059
DIST-CO-RTE-PM07-LA-210-R35.9/R52.2
Award Date04/04/2022
Closeout Date09/24/2024
Work DescriptionCOLD PLANE OVERLAY, INDIVIDUAL REPLACEMENT SLAB AND TRAFFIC STRIPING.
Location DescriptionLOS ANGELES COUNTY FROM HIGHLAND AVENUE UNDERCROSSING IN DUARTE TO SAN ANTONIO WASH BRIDGE IN CLAREMONT.
QA Service Level1 (Verified on 04/19/2022)

Sample Information

Sample Taken Date04/24/2023 Sample Unique Key60
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/01/2023
Sample typeVerification A brief description of the sampleAsphalt Rubber Binder
The quantity of what the sample constitutes1 Quart Can From where was the sample collectedSupplier
First name of sampler or witnessed byVulcan QC Last name of sampler or witnessed byVulcan QC
Title of sampler Telephone number of sampler
Laboratory sample identification0227-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan-Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2023-04-24-60
DIME Test ID: 2023-04-24-60-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2023-05-11

Test Results


Input Type: Calculated
Tester's full name: Sm Ali
Date of test: 05/03/2023
Temperature: 25 C
Final Dial reading (F1): 66 mm
Ball Penetration (P1): 0 mm
Final Dial reading (F2): 67 mm
Ball Penetration (P2): 0 mm
Final Dial reading (F3): 68 mm
Ball Penetration (P3): 0 mm
Resilience 1: 34 %
Resilience 2: 33 %
Resilience 3: 32 %
Average Resilience: 33 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/11/2023