Summary for Test 2023-03-13-29-3

Test performed: ASTM D5329-16

Project Information

Project IdentifiersProject ID: 213750
DEA: 120K0224
EFIS: 1214000097
DIST-CO-RTE-PM12-ORA-5-14.5/17.1
Award Date03/05/2019
Closeout DateNot set
Work DescriptionSouth County Improvement Project (Phase 2 - Oso/Alicia) CONST BRIDGES, RW, SW, HMA PVMT, JPCP, DRAINAGE, AND ELECT SYSTEMS.
Location DescriptionORANGE COUNTY IN MISSION VIEJO AND LAGUNA HILLS FROM 0.7 MILE SOUTH OF OSO PARKWAY OVERCROSSING TO 0.3 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING
QA Service Level1 (Verified on 04/15/2019)

Sample Information

Sample Taken Date03/13/2023 Sample Unique Key29
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/18/2023
Sample typeVerification A brief description of the sampleAsphalt Rubber Binder
The quantity of what the sample constitutes1 Quart Can From where was the sample collectedSupplier
First name of sampler or witnessed byDavid Last name of sampler or witnessed byNguyen
Title of sampler Telephone number of sampler
Laboratory sample identification0206-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA-Irvine Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2023-03-13-29
DIME Test ID: 2023-03-13-29-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2023-05-11

Test Results


Input Type: Calculated
Tester's full name: Sm Ali
Date of test: 04/20/2023
Temperature: 25 C
Final Dial reading (F1): 84 mm
Ball Penetration (P1): 2 mm
Final Dial reading (F2): 83 mm
Ball Penetration (P2): 1 mm
Final Dial reading (F3): 81 mm
Ball Penetration (P3): 0 mm
Resilience 1: 18 %
Resilience 2: 18 %
Resilience 3: 19 %
Average Resilience: 18 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/11/2023