Summary for Test 2023-04-05-17-6
Test performed: CTM 523-May 2020Project Information
| Project Identifiers | Project ID: 215425 DEA: 06360244 EFIS: 0613000005 |
|---|---|
| DIST-CO-RTE-PM | 06-TUL-99-30.6/35.2 |
| Award Date | 04/23/2021 |
| Closeout Date | Not set |
| Work Description | Widen Freeway & Bridge Construction (Concrete Bridge) |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 11/01/2021) |
Sample Information
| Sample Taken Date | 04/05/2023 | Sample Unique Key | 17 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/05/2023 |
| Sample type | Quality Assurance | A brief description of the sample | JPCP pour |
| The quantity of what the sample constitutes | 76 | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Neale | Last name of sampler or witnessed by | Brown |
| Title of sampler | Telephone number of sampler | 6615498281 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | tulare concrete plant | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 72444NOM |
|---|---|---|---|
| The truck number from where the sample was collected | 0697 | The batch plant ticket number from where the sample was collected | 123820 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | back of truck load 8 | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-04-05-17
DIME Test ID: 2023-04-05-17-6
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2023-05-04
Test Results
Number of specimens: 3
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 05/04/2023
Identification number: 97
Width of specimen: 6.0 inch
Width of specimen 2: 6.0 inch
Width of specimen 3: 6.0 inch
Depth of specimen: 6.2 inch
Depth of specimen 2: 6.2 inch
Depth of specimen 3: 6.1 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 9810 lb
Maximum load applied 2: 9590 lb
Maximum load applied 3: 9330 lb
Curing history and apparent moisture condition of the specimen: Good and Standard Curing Beams
If specimen was capped, ground or if leather shims were used: Leather shims were used
Defects in specimen: 0
Age of specimen: 29 days
Age of specimen in hours: 0 hours
Modulus of rupture: 770 psi
Modulus of rupture 2: 760 psi
Modulus of rupture 3: 770 psi
Modulus of rupture average: 765 psi
General comments (publicly viewable) (Max 1000 characters): Standard Curing beams for 28 days
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| 06-360244_37052_230405_29D_97 | 185.58 KB | 05/04/2023 | 2023-04-05-17-6 | Info |
Test was verified on 5/4/2023 ✔