Summary for Test 2023-04-14-47-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 215456 DEA: 07293604 EFIS: 0713000238 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-405-14.3/15.8 |
| Award Date | 05/26/2021 |
| Closeout Date | 07/03/2025 |
| Work Description | CONSTRUCT AUXILIARY LANE AND WIDEN ON AND OFF RAMPS. |
| Location Description | LOS ANGELES COUNTY IN TORRANCE BETWEEN WESTERN AVENUE UNDERCROSSING AND WEST 182ND STREET |
| QA Service Level | 1 (Verified on 07/07/2021) |
Sample Information
| Sample Taken Date | 04/14/2023 | Sample Unique Key | 47 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/14/2023 |
| Sample type | Quality Assurance | A brief description of the sample | Native Material |
| The quantity of what the sample constitutes | 17250 sqft | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Ruben | Last name of sampler or witnessed by | Lopez |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 23-0433 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | n/a | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | CTM 231 Test Holes | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-04-14-47
DIME Test ID: 2023-04-14-47-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-05-03
Test Results
Method Type:: Standard Count
Number of Tests:: 5
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Ruben Lopez
Date of test: 04/14/2023
Gage No.: 86217
Test No.: 1
Nuclear By: Ruben Lopez
Non-Bias Plan No.: 2
Depth: 5
Material No.: Subgrade
Material Type: Native Material
Impact By: Ruben Lopez
Standard Count Density: 2517 g/cc
Count or Density 1: 2610 g/cc
Count or Density 2: 2459 g/cc
Count or Density 3: 2593 g/cc
Count or Density 4: 2701 g/cc
Count or Density 5: 2600 g/cc
Standard Count Moisture: 783 g/cc
Moisture Count 1: 178 g/cc
Moisture Count 2: 188 g/cc
Moisture Count 3: 200 g/cc
Moisture Count 4: 100 g/cc
Moisture Count 5: 87 g/cc
Sum of Count or Density: 12963 g/cc
Average of Count or Density: 2593 g/cc
Sum of Moisture Count: 753 g/cc
Average of Moisture Count: 151 g/cc
Count Ratio Density: 1.03
Count Ratio Moisture: 0.19
Calculated Percent Relative Compaction: 94.7 %
Reported Percent Relative Compaction: 95 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/3/2023 ✔