Summary for Test 2016-12-01-3-1

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 209114
DEA: 040A7104
EFIS: 0400000160
COOP: 042550
DIST-CO-RTE-PM04-ALA-880-28.4/29.2
Award Date04/30/2014
Closeout Date07/23/2020
Work DescriptionWIDEN ROADS, RECONSTRUCT RAMPS WITH HMA, REPLACE 2 CONC OVERCROSSINGS.
Location DescriptionALAMEDA COUNTY IN ALAMEDA AND OAKLAND FROM 0.2 MILE SOUTH OF 29TH AVENUE OVERCROSSING TO 0.3 MILE NORTH OF 23RD AVENUE OVERCROSSING.
QA Service Level1 (Verified on 10/11/2013)

Sample Information

Sample Taken Date12/01/2016 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing12/05/2016 Sample typeQuality Assurance
A brief description of the sampleCoupon Casting The quantity of what the sample constitutes1
From where was the sample collectedDistributor First name of sampler or witnessed byDebbie
Last name of sampler or witnessed byOzuna Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameManchester Metals
Transportation Laboratory (TL) NumberNA Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)16K16
Part Number (s)68 27 212 Material SpecificationA536
Grades65-45-12 Metal Foundry Manufacturer (Mill)Manchester Metals
Prestressing ManufacturerDSI

Test Details

DIME Sample ID: 2016-12-01-3
DIME Test ID: 2016-12-01-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2016-12-08

Test Results


Number of Samples: 1
Input Type: Calculated
Tester's full name: Fred
Date of test: 12/07/2016
UTM: 67KIP
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1091960.4930.1909494438785012.1Fred

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 12/8/2016 ✔