Summary for Test 2016-12-01-4-2

Test performed: ASTM A615-15

Project Information

Project IdentifiersProject ID: 210735
DEA: 071193U4
EFIS: 0713000007
DIST-CO-RTE-PM07-LA-10-37.2/42.4
Award Date11/16/2015
Closeout Date07/11/2022
Work DescriptionCONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location DescriptionIN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA
QA Service Level1 (Verified on 03/07/2016)

Sample Information

Sample Taken Date12/01/2016 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/05/2016
Sample typeQuality Assurance A brief description of the sampleThreaded Bar
The quantity of what the sample constitutes2 From where was the sample collectedDistributor
First name of sampler or witnessed byKen Last name of sampler or witnessed byVarela
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameGerdau Farrar Transportation Laboratory (TL) NumberC939305
Inspector Lot Number from the Transportation Laboratory (TL) FormL0813716 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar TypeDeformed Rebar Size11
Nut Specification for Threaded BarASTM A897 System ManufacturerDSI
Epoxy Coating ColorNA Threaded Bar Application
Coating StandardsUncoated Bar Heat Number(s)6214252602
Nut Heat Number(s)H296 Bar Lot NumberUnknown
Nut Lot NumberUnknown Coupler Heat Number(s)
Coupler Grade

Test Details

DIME Sample ID: 2016-12-01-4
DIME Test ID: 2016-12-01-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2016-12-06

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 12/06/2016
UTM: 400KIP
Temperature: 72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
12#11 Bar Heat #6214252602, Nut Heat #H269L08-137-161.56116097754570A615 Threaded Bar and NutBrian

General comments (publicly viewable) (Max 1000 characters): A615 Threaded Bar and Nut
Test Graph
Source: Partner Data Point File

Test was verified on 12/6/2016