Summary for Test 2023-04-05-43-1
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 994678 DEA: 020J7704 EFIS: 0219000158 |
|---|---|
| DIST-CO-RTE-PM | 02--299-21.6/22.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Construct turnouts in Trinity County at and near del Loma from 1.8 miles east of Big Mountain Road to 0.6 mile west of Big French Creek Road. |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 08/09/2023) |
Sample Information
| Sample Taken Date | 04/05/2023 | Sample Unique Key | 43 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/05/2023 | Sample type | Preliminary |
| A brief description of the sample | Soil for culvert recommendation, C-5 | The quantity of what the sample constitutes | Culvert Recommendation C-5 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Brian |
| Last name of sampler or witnessed by | Steiner | Title of sampler | AAME |
| Telephone number of sampler | Laboratory sample identification | D79210 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | In Situ | |
| Transportation Laboratory (TL) Number | 895808 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | DI at 02-TRI-299-19.27, 0.0-0.5 foot | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-04-05-43
DIME Test ID: 2023-04-05-43-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2023-04-27
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 04/21/2023
Minimum soil resistance of the lab measurement: 8100 Ohms
Soil sample temperature: 19.6 C
Soil box constant: 1
pH of soil: 7.16
Minimum soil resistance corrected to 15.5: 8930.25 Ohm-cm
Minimum soil resistivity at 15.5: 8930 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=7.16,
ρ=8930Ω∙cm
Test was verified on 4/27/2023 ✔