Summary for Test 2023-04-24-19-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 214640 DEA: 042J7204 EFIS: 0415000016 |
---|---|
DIST-CO-RTE-PM | 04-CC-580-1.17 |
Award Date | 02/25/2021 |
Closeout Date | 12/01/2023 |
Work Description | STEGE DRAIN SUPER-STRUCTURE, PRECAST VOIDED SLABS |
Location Description | CONTRA COSTA COUNTY IN RICHMOND FROM 0.3 MILE EAST OF STEGE DRAIN BRIDGE TO 0.3 MILE WEST OF BAYVIEW AVENUE OVERCROSSING |
QA Service Level | 1 (Verified on 01/27/2020) |
Sample Information
Sample Taken Date | 04/24/2023 | Sample Unique Key | 19 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/25/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1/2 HMA Type A |
The quantity of what the sample constitutes | 4 Boxes | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Benito | Last name of sampler or witnessed by | Salinas |
Title of sampler | QC Technician | Telephone number of sampler | 7072878604 |
Laboratory sample identification | Rich_23_109 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Vallejo | Transportation Laboratory (TL) Number | C911352 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | 1 | Structure unique identifier | |
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | 1 |
Sublot number | 1 | HMA Mix Number | 320914 |
Test Details
DIME Sample ID: 2023-04-24-19
DIME Test ID: 2023-04-24-19-1
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-07-27
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Augusto Rios
Date of test: 04/25/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 3087.1 g
Mass of the specimen and specimen basket assembly prior to ignition: 4734.1 g
Mass of HMA Sample prior to ignition: 1647.0 g
Mass Loss: 124.7 g
Mass of aggregate remaining after ignition: 1522.3 g
Correction Factor (Percent by mass of HMA Specimen): 1.60 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.18 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 5.79 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/27/2023 ✔