Summary for Test 2016-11-30-1-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210808
DEA: 020E0904
EFIS: 0200000016
DIST-CO-RTE-PM02-SHA-5-R29.3/R31.1,R45.0/R45.8
Award Date02/03/2016
Closeout Date10/21/2020
Work DescriptionREPLACE BRIDGE, REALIGN ROADWAY AND SEISMIC RETROFIT
Location DescriptionIN SHASTA COUNTY ABT 8 MI N OF SHASTA LAKE CTY AND NEAR LAKEHEAD FRM TURNTABLE BAY O/C TO 0.1 MI N OF O'BRIEN SRRA & FRM 0.4 MI S TO 0.3 MI N OF DOG CREEK BRIDGE.
QA Service Level1 (Verified on 09/23/2015)

Sample Information

Sample Taken Date11/30/2016 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing11/30/2016 Sample typeQuality Assurance
A brief description of the sampleBartec Couplers The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byD
Last name of sampler or witnessed byMann Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameNucor Dextra America
Transportation Laboratory (TL) NumberC691783 Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDextra America Intermediate Assembler or FabricatorUnknown
Rebar Size14 Coupler ModelBartec
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)MM13102607 Lot C02 Rebar Heat Number(s)SE15101860
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2016-11-30-1
DIME Test ID: 2016-11-30-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2016-12-01

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 12/01/2016
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12C02#14/43mm2.25021998597771Brittle BreakBrian

General comments (publicly viewable) (Max 1000 characters): Brittle Break
Test Graph
WARNING: No graph data imported from Instron machine.

Test was verified on 12/1/2016 ✔