Summary for Test 2023-04-22-6-1

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 993804
DEA: 043J0624
EFIS: 0419000534
DIST-CO-RTE-PM04-SM-101-16.5/23.0
Award Date08/24/2022
Closeout Date04/10/2024
Work DescriptionCOLD PLANE AND PLACE HMA, REPLACE GUARDRAIL AND CURB RAMPS.
Location DescriptionSAN MATEO COUNTY AT VARIOUS LOCATION FROM BROADWAY OVERCROSSING TO 0.2 MILE NORTH OF OYSTER POINT BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 05/19/2022)

Sample Information

Sample Taken Date04/22/2023 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/24/2023
Sample typeQuality Assurance A brief description of the samplePCC Concrete Sand Fine Agg
The quantity of what the sample constitutes35 cu yd From where was the sample collectedJob Site
First name of sampler or witnessed byLuis Last name of sampler or witnessed byMagana
Title of sampler Telephone number of sampler2092250104
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVanguard Batch Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Orca Quarry, Port Mcneill, B.C.
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile @ Jobsite
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberHE4X4BM Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-04-22-6
DIME Test ID: 2023-04-22-6-1
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2023-05-03

Test Results


Number of tests: 3
Input Type: Measured
Tester's full name: Luis Magana
Date of test: 04/25/2023
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 5.2
Sand reading (test 1): 4.4
Clay reading (test 2): 5.3
Sand reading (test 2): 4.4
Clay reading (test 3): 5.1
Sand reading (test 3): 4.3
Sand equivalent (test 1): 85
Sand equivalent (test 2): 83
Sand equivalent (test 3): 85
Sand equivalent before temperature correction: 85
Sand equivalent after temperature correction: 85
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/3/2023