Summary for Test 2016-11-23-2-1

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 3825
DEA: 07138204
EFIS: 0700000142
DIST-CO-RTE-PM07-LA-47,103-3.5/4.6,0.0/1.1
Award Date06/30/2011
Closeout Date07/14/2022
Work DescriptionREPLACE STEEL BRIDGE WITH CIP PS CONCRETE BOX GIRDER BRIDGE AND RAMPS.
Location DescriptionLOS ANGELES COUNTY IN LONG BEACH AND LOS ANGELES ON ROUTE 47 FROM OCEAN BOULEVARD TO ROUTE 103 JUNCTION AND ON ROUTE 103 FROM ROUTE 47 JUNCTION TO ANAHEIM STREET OVERHEAD
QA Service Level1 (Verified on 03/29/2012)

Sample Information

Sample Taken Date11/23/2016 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing11/30/2016 Sample typeQuality Assurance
A brief description of the sampleCoupon Casting The quantity of what the sample constitutes1
From where was the sample collectedDistributor First name of sampler or witnessed byDebbie
Last name of sampler or witnessed byOzuna Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameManchester Metals
Transportation Laboratory (TL) NumberNA Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)9K16
Part Number (s)68 27 212 Material SpecificationA536
Grades65-45-12 Metal Foundry Manufacturer (Mill)Manchester Metals
Prestressing ManufacturerDSI

Test Details

DIME Sample ID: 2016-11-23-2
DIME Test ID: 2016-11-23-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2016-12-01

Test Results


Number of Samples: 1
Input Type: Calculated
Tester's full name: Arnold
Date of test: 12/01/2016
UTM: 67KIP
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
19K160.4950.1924533118802012.4Arnold

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 12/1/2016 ✔