Summary for Test 2023-04-11-51-1
Test performed: AASHTO T209-22Project Information
| Project Identifiers | Project ID: 994513 DEA: 043Y0604 EFIS: 0423000193 |
|---|---|
| DIST-CO-RTE-PM | 04-MRN-1-var/var |
| Award Date | 02/12/2023 |
| Closeout Date | 03/11/2024 |
| Work Description | PAVEMENT REPAIR |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 04/11/2023 | Sample Unique Key | 51 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/14/2023 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 HMA Type A | The quantity of what the sample constitutes | 2 Boxes |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Casey |
| Last name of sampler or witnessed by | Farington | Title of sampler | QC Technician |
| Telephone number of sampler | 7072285999 | Laboratory sample identification | Rich_23_108 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | 3/4 HMA Type A | |
| Transportation Laboratory (TL) Number | C727118 | Inspector Lot Number from the Transportation Laboratory (TL) Form | 1 |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 8 | HMA Mix Number | 700SPW16 |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-04-11-51
DIME Test ID: 2023-04-11-51-1
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-04-24
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Augusto Rios
Date of test: 04/19/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7371.8 grams
Mass of oven-dry sample in air for Sample 1: 2605.3 grams
Mass of container filled with the sample and water for Sample 1: 8979.7 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.612
Theoretical maximum density at 25°C (77°F): 2604.4 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/24/2023 ✔