Summary for Test 2023-04-06-39-1
Test performed: AASHTO T209-22Project Information
| Project Identifiers | Project ID: 994513 DEA: 043Y0604 EFIS: 0423000193 |
|---|---|
| DIST-CO-RTE-PM | 04-MRN-1-var/var |
| Award Date | 02/12/2023 |
| Closeout Date | 03/11/2024 |
| Work Description | PAVEMENT REPAIR |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 04/06/2023 | Sample Unique Key | 39 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/07/2023 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 HMA Type A | The quantity of what the sample constitutes | 2 Boxes |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Casey |
| Last name of sampler or witnessed by | Farington | Title of sampler | QC Technician |
| Telephone number of sampler | 7072285999 | Laboratory sample identification | Rich_23_098 |
| Linked DIME Sample ID | 2023-04-06-32 | The fabricator/manufacturer/facility name | BoDean Santa Rosa |
| Transportation Laboratory (TL) Number | C727201 | Inspector Lot Number from the Transportation Laboratory (TL) Form | 1 |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 7 | HMA Mix Number | 700SPW16 |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-04-06-39
DIME Test ID: 2023-04-06-39-1
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-04-20
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Augusto Rios
Date of test: 04/11/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7371.8 grams
Mass of oven-dry sample in air for Sample 1: 2666.6 grams
Mass of container filled with the sample and water for Sample 1: 9013.9 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.603
Theoretical maximum density at 25°C (77°F): 2595.5 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/20/2023 ✔