Summary for Test 2023-04-05-17-5

Test performed: CTM 523-May 2020

Project Information

Project IdentifiersProject ID: 215425
DEA: 06360244
EFIS: 0613000005
DIST-CO-RTE-PM06-TUL-99-30.6/35.2
Award Date04/23/2021
Closeout DateNot set
Work DescriptionWiden Freeway & Bridge Construction (Concrete Bridge)
Location DescriptionNot set
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date04/05/2023 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/05/2023
Sample typeQuality Assurance A brief description of the sampleJPCP pour
The quantity of what the sample constitutes76 From where was the sample collectedSupplier
First name of sampler or witnessed byNeale Last name of sampler or witnessed byBrown
Title of sampler Telephone number of sampler6615498281
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nametulare concrete plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number72444NOM
The truck number from where the sample was collected0697 The batch plant ticket number from where the sample was collected123820
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedback of truck load 8 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-04-05-17
DIME Test ID: 2023-04-05-17-5
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2023-04-14

Test Results


Number of specimens: 3
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: James Watson
Date of test: 04/14/2023
Identification number: 96
Width of specimen: 6.0 inch
Width of specimen 2: 6.0 inch
Width of specimen 3: 6.0 inch
Depth of specimen: 6.1 inch
Depth of specimen 2: 6.2 inch
Depth of specimen 3: 6.1 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 7050 lb
Maximum load applied 2: 6950 lb
Maximum load applied 3: 6690 lb
Curing history and apparent moisture condition of the specimen: Good
If specimen was capped, ground or if leather shims were used: Leather shims were used
Defects in specimen: 0
Age of specimen: 8 days
Age of specimen in hours: 0 hours
Modulus of rupture: 575 psi
Modulus of rupture 2: 555 psi
Modulus of rupture 3: 540 psi
Modulus of rupture average: 555 psi
General comments (publicly viewable) (Max 1000 characters): Field Curing Beam : 550 psi required for opening traffic

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-360244_37052_230405_09D_96pdf185.28 KB04/14/20232023-04-05-17-5   Info

Test was verified on 4/14/2023