Summary for Test 2023-04-11-15-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 993482
DEA: 060V2804
EFIS: 0616000124
DIST-CO-RTE-PM06-KER-184-L0.9/L1.1
Award Date02/24/2022
Closeout Date02/26/2024
Work DescriptionPLACE HMA AND MINOR CONCRETE, REPLACE ELECTRICAL & LIGHTING SYSTEMS.
Location DescriptionKERN COUNTY NEAR LAMONT FROM 0.1 MILE SOUTH TO 0.1 MILE NORTH OF SUNSET BOULEVARD
QA Service Level1 (Verified on 01/03/2022)

Sample Information

Sample Taken Date04/11/2023 Sample Unique Key15
Date that the sample was received by the laboratory/organization performing the testing04/11/2023 Sample typeDepartment Acceptance
A brief description of the sampleNative Soil- sitty FM sand mod. clay and gravel The quantity of what the sample constitutes40 lbs
Sample sizeNot set From where was the sample collectedJob Site
First name of sampler or witnessed byJames Last name of sampler or witnessed byWatson
Title of samplerTester Telephone number of sampler6615498281
Laboratory sample identification38 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSta 56+70 to 60+44 Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedTest holes at jobsite
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2023-04-11-15
DIME Test ID: 2023-04-11-15-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-04-11

Test Results


Method Type:: Standard Count
Number of Tests:: 5
Common Test Maximum Used:: Yes
Input Type: Measured
Tester's full name: James Watson
Date of test: 04/11/2023
Gage No.: 30699
Test No.: 38
Nuclear By: James Watson
Non-Bias Plan No.: 8 even
Depth: 8
Material No.: no data
Material Type: Brown- sandy silt, some clay and gravel
Impact By: James Watson
Standard Count Density: 1958
Count or Density 1: 916
Count or Density 2: 1210
Count or Density 3: 1127
Count or Density 4: 982
Count or Density 5: 1107
Standard Count Moisture: 628
Moisture Count 1: 111
Moisture Count 2: 100
Moisture Count 3: 86
Moisture Count 4: 102
Moisture Count 5: 130
Density: 2.14
Moisture: 0.13
Sum of Count or Density: 5342
Average of Count or Density: 1068
Sum of Moisture Count: 529
Average of Moisture Count: 106
Count Ratio Density: 0.55
Count Ratio Moisture: 0.17
Calculated Percent Relative Compaction: 100 %
Reported Percent Relative Compaction: 100 %
General comments (publicly viewable) (Max 1000 characters): North end 184 leg Sta 56+70 to 60+44 elevation: 1.7 BFG width 40 ft probe 8"

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-0V2804_37016_230411_35_39pdf574.49 KB04/11/20232023-04-11-15-1   Info

Test was verified on 4/11/2023 ✔