Summary for Test 2023-03-03-47-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 215129 DEA: 050N73U4 EFIS: 0520000166 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-101-7.3/9.6 |
| Award Date | 10/22/2020 |
| Closeout Date | 12/11/2023 |
| Work Description | !!Please CC Office Engineer Gabrielle Herrera on reports to RE and SR!! Segment 4C - Summerland: Construct HOV lanes and rehabilitation. Source inspection of sign structure trusses, lighting structures, steel soldier piles, epoxy coated rebar, |
| Location Description | SUMMERLAND FROM 0.2 MILES NORTH OF PARDARO LANE OVERCROSSING TO SAN YSIDRO CREEK BRIDGE |
| QA Service Level | 1 (Verified on 08/24/2020) |
Sample Information
| Sample Taken Date | 03/03/2023 | Sample Unique Key | 47 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/31/2023 | Sample type | Department Acceptance |
| A brief description of the sample | 4x8 concrete cylinders | The quantity of what the sample constitutes | 19 CY |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Jesse |
| Last name of sampler or witnessed by | Gomez | Title of sampler | |
| Telephone number of sampler | 8055501704 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Martin Marietta Goleta | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 63511N0P |
|---|---|---|---|
| The truck number from where the sample was collected | 675 | The batch plant ticket number from where the sample was collected | 3433009 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Discharge from concrete truck into wheelbarrow | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-03-03-47
DIME Test ID: 2023-03-03-47-1
Testing Lab: CT D05 - Carpinteria Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-04-03
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Darren Harper
Date of test: 03/31/2023
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.02 in
Average diameter of cylinder 2: 4.02 in
Average diameter of cylinder 3: 4.02 in
Maximum load on cylinder 1: 48370 lb
Maximum load on cylinder 2: 58090 lb
Maximum load on cylinder 3: 54230 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 4
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.69 in^2
Cross sectional area of cylinder 2: 12.69 in^2
Cross sectional area of cylinder 3: 12.69 in^2
Compressive strength of cylinder 1: 3811.7 psi
Compressive strength of cylinder 2: 4577.6 psi
Compressive strength of cylinder 3: 4273.4 psi
Compressive strength (to nearest 10 psi): 4220 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/3/2023 ✔