Summary for Test 2023-02-07-47-4

Test performed: CTM 229-June 2011

Project Information

Project IdentifiersProject ID: 215677
DEA: 044G0804
EFIS: 0412000332
COOP: 042676
DIST-CO-RTE-PM04-SOL-80-R10.4/30.2
Award Date01/18/2022
Closeout DateNot set
Work DescriptionHighway widening, overhead signs, and electronic toll system.
Location DescriptionIn Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
QA Service Level1 (Verified on 04/11/2022)

Sample Information

Sample Taken Date02/07/2023 Sample Unique Key47
Date that the sample was received by the laboratory/organization performing the testing02/10/2023 Sample typeAnnual Source Testing
A brief description of the sampleMan- SAND The quantity of what the sample constitutes6 Bags
From where was the sample collectedSource First name of sampler or witnessed byNot Witness
Last name of sampler or witnessed byEduardo P Title of samplerQC Manager
Telephone number of sampler(424) 3241966 Laboratory sample identificationCon_23_148
Linked DIME Sample ID The fabricator/manufacturer/facility nameCemex Madison Cache Creek
Transportation Laboratory (TL) NumberC422-305 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-57-0008
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant stock pile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-02-07-47
DIME Test ID: 2023-02-07-47-4
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 229-June 2011: Method of Test for Durability Index
Test Release Date: 2023-03-28

Test Results


What test(s) are being run?: Fine durability only
Input Type: Calculated
Tester's full name: District 4 Hayward Lab
Date of test: 03/23/2023
Fine durability index: 82
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/28/2023 ✔